Use these cables between a battery bank and an inverter, fuse or power center. They have flexible stranded UL Listed copper wire and 3/8″ diameter lugs. Lug barrels are covered with glue-filled heat-shrink tubing.
Wire Gauge and Length
4/0 AWG – 5 & 10 ft lengths
2/0 AWG – 5 & 10 ft lengths
2 AWG – 3 & 5 ft lengths
Heavy Duty Battery Interconnects
Use these cables between individual battery cells or between battery banks. Circuits protected by 250-amp breakers or 400-amp fuses should use 4/0 cables. Use 2/0 cables for 175-amp breakers and 200-amp fuses. Use #2 cables for 110-amp or smaller fuses or breakers. Cables with 1 red end and 1 black end are used for series battery interconnects. Cables with white ends are for negative battery parallel jumpers.
Wire Size and Length
2 AWG – 9 in, 12 in, & 20 in.
2/0 AWG – 9 in, 12 in, & 20 in.
4/0 AWG – 12 in & 20 in.
Light Duty Battery Interconnects
Use these cables between batteries where charge and discharge current will not exceed 50 amps. These cables are often used in golf cart and automotive applications.
Wire Size and Length
6 AWG – 9 in. & 12 in.
4 AWG – 24 in. & 36 in.
These UL listed lugs are made from tin-plated copper tubing with 3/8″ holes. Solder or crimp to stranded cable.
Ring Size
6 AWG, 4 AWG, 2 AWG, 2/0 AWG, & 4/0 AWG
Use this tubing to insulate copper lugs and compression terminals. Tubing shrinks and glue inside melts when heated with a heat gun or torch, sealing wires against corrosion and moisture. Maximum shrinkage is listed below. Sold in 6 in lengths.
Description
1/2″ x 6″ Black
1/2″ x 6″ Red
3/4″ x 6″ Black
3/4″ x 6″ Red
1″ x 6″ Black
1″ x 6″ Red
Tray Cable (TC)
This 2-conductor flexible wire is excellent for outdoor applications like PV array lead-in and subarray wiring. It may be buried directly in the ground or exposed to direct sunlight. 10-and 12-gauge are good for array interconnects. UL Listed, stranded type THHN/THWN conductors. Conductor insulation is red and blck/
Available Wire Size
8 AWG, 10 AWG, 12 AWG, 16 AWG, & 18 AWG
This cable has two flexible stranded conductors covered with a vinyl jacket. It is commonly used for low voltage house wiring. Since it is stranded, it can be used in boats and RVs where vibration is encountered. Conductor insulation is black and white.
Available Wire Size
#8 – 2C, #10-2C, #12- 2C, #14-2C
Pump Cable
10/2 without ground pump cable is for the SHURflo 9300 submersible pump. 2-conductor with ground pump cable is required for Grundfos SQFlex and SQ AC pumps.
This 3-conductor, 22-gauge direct-burial wire can be used between water level sensors and pump controls in pumping applications where you must sense the wter level in a remote tank or in a well.
Available Wire Size
10/2 without ground, 12/2 with ground, 10/2 with ground, 8/2 with ground, sensor wire 22/3, splice kit
Direct Burial / Sunlight Resistant Cable
Type USE single-conductor copper wire for lead-in from PV arrays, wind and hydroelectric systems. It may be used for AC or DEC wiring up to 600V. Insulation is blck crosslinked polyethylene. UL Listed, USE-2 RHH / RHW-2.
PV Wire Sunlight Resistant Cable
This single conductor insulted with heat and moisture resistant, cross-linked polyethylene insulation, (Type USE-2), with an overall flame and sunlight resistant, Zero halogen, limited smoke, zero lead jacket meets the 2008 NEC code for use with transformerless inverters. UL Listed as Type PV Cable Conductors UL854 (#16 per UL 66) ICEA S-95-658/NEMA WC-70.
This fine-stranded, very flexible cable is UL Listed for use as battery cable. It is rated MTW or THW or AWM, 600-volt, sunlight resistant, direct burial, 105 degrees C. Available with red or black insulation.
Available Wire Sizes
X-Flex battery cable 4/0, X-Flex battery cable 2/0, X-Flex 2 AWG
Multi-Contact
Cables and Connectors
The Multi-Contact Solarline family of connectors delivers a flexible system solution for time-saving, dependable series-cabling of solar modules. All module manufacturers supply their grid-tie modules with pre-assembled output cables, tested and ready for connection. This saves considerable time during an installation and greatly increases reliability over wire junction boxes. These cable couplers are fully touch-protected and designed for up to 1000 volts and 30 amps. They are also waterproof. For parallel connection of modules in 12-to 48-volt systems, Multi-Concaaact makes branch connectors for use with currents up to 30 amps.
For the past few years, modules have come with Mult-Contact Solarline 1 connectors which have a soft rubber insulator. In 2007, PV manufacturers began switching to Multi-Contact Solarline 2 locking connectors to meet future electrical code requirements.
The Multi-Contact plug-and-play connector system allows for the PV arrays to be pre-assembled and pre-wired in the shop or on site. We stock both styles of connectors for use with 10 AWG or 12 AWG USE-2 stranded wire. Proper crimping to the wire and insulator assembly requires special tools. We stock standard lengths of assembled cables and adapters to go between Solarline 1 and Solarline2 connectors and the tools required for on-site assembly of cables.
MC3 Solarline 1 Array Output Cables
These cables have the old style Multi-Contact soft rubber connectors on each end. Use these output cables between PV arrays with Multi-Contact cable outputs, and junction boxes or grid-tie inverters. They have a male connector on one end and a female connector on the other end. Use them to extend module output cables or cut anywhere along the wire to obtain the needed len gth of male and female cable to run from the ends of a module string to a combiner box or to an inverter. Made with black #10 AWG USE-2 sunlight-resistant cable.
Cable Lengths
6 ft., 15 ft., 30 ft., 50 ft., 70 ft., & 100 ft.
Tyco SolarLok Array Output Cables
These cables have Tyco SolarLok connectors to match the connectors on some SCHOTT, Day4Energy, GE and CSI Solar Modules. These cables have a neutral male at one end and a negative female at the other so they can be used to connect to a roof-top combiner. Made with black #10 AWG USE-2 sunlight-resistant cable.
MC4 Solarline 2 Array Output Cables
These cables have the newer, snap-together Multi-Contact hard plastic connectors on each end. Use these output cables between PV arrays with Multi-Contact caable outputs, and junciton boxes or grid-tie inverters. The new Solarline 2 cables have a male connector on one end and a female connector on the other end. Use them to extend module output cables or cut anywhere along the wire to obtain the needed length of male and female cable to run from the ends of a module string to a combiner box or to an inverter.
MC4 Solarline 2 PV-Wire Cables
These cables have the newer, snap-together Multi-Contact hard plastic connectors on each end and are made with PV-Wire that has an extra layer of insulation for use on ungrounded arrays in conjunction with transformerless inverters. This type of wire is required to meet the 2008 NEC if you are using a transformerless inverter.
MC4 Solarline 2 to MC3 Solarline 1 Adaptors
Use these adapters to connect new-style modules to old-style Solarline 1 cables or anywhere a transition is needed between Solarline 1 and Solrline 2 cables.
MC4 Solarline 2 to Tyco SolarLok Adaptors
Use these adapters to connect solar modules with Tyco connectors to MC4 cables.
Tyco SolarLok Connectors
These connectors can be assembled quickly on site by a contractor allowing assembly of custom cables at the job site. A special crimping tool and wrench set are required to assemble the connector. For10 AWG USE-2 wire. Sold in packs of 25.
MC3-Solarline 1 Branch Connectors
These waterproof Y-connectors make it possible to parallel wire PV modules with Multi-Contact output cables. Maximum current allowed through connectors is 30 MPs.
MC4-Solarline 2 Branch Connectors
These waterproof Y-connectors make it possible to parallel wire PV modules with Multi-Contact output cables. Maximum current allowed through connectors is 30 MPs.
MC3-Solarline 1 Connectors
These connectors can be assembled quickly on site by a contractor allowing assembly of custom cables at the job site. A special crimping tool and boot installation tool are required to assemble the connector. For 10 AWG USE-2 wire. Packs of 25.
MC4-Solarline 2 Connectors
The connector can be assembled quickly on site by a contractor allowing assembly of custom cables at the job site. A special crimping tool and wrench set are required to assemble the connector. We have connectors for 10 AWG USE-2 wire and for larger diameter 10 AWG PV wire. Sold in Packs of 25 connectors.